www.coopernotification.com
20
Single Zone CO Port Paging Applications
Talkbatterycanbeprovidedwithalteredandregulated24VDCpowersupplyasillustratedbythe
following diagram
Note: This diagram shows the output of the telephone system feeding the input of a typical Wheelock ampli-
er for distribution on a 70 volt system. That same output could also directly feed self-amplied speakers or
Wheelock talk back speakers in a similar manner.
Accessories
Now that we have built a paging system and interfaced it with a telephone system let’s take a look at some different
accessories that can be utilized.
Common Audible
If the telephone system has no night ring feature, you can activate a tone generator by using a common audible, such
as a Wheelock CA-312-1 or CA-622-1. These devices connect to all of the CO lines ahead of the EKSU or PBX main-
frame and then put out a common ring signal whenever a call comes in on any of the lines. This common output can
be either a dry contact or network ringing voltage, either of which can be used to activate a tone generator — or other
types of signals for that matter.
PRM-150 Pre-Amplier
Besides correcting for proper impedance matching and compensating for long wire runs, the PRM-150 functions as a
mastervolumecontrolforagroupof600Ohm,SelfAmpliedspeakers.ThePRM-150requires24VDC.
TELEPHONE SYSTEM
UNUSED CO PORT
2 WIRE
CABLE
2 WIRE
CABLE
POWER SUPPLY
(+) (-) SPARE
TELEPHONE
INPUT
Common Audible Interfaces
Wheelock’s Series CA-622-1 Common Audible Control Unit can
monitoruptosixtelephonelinestoprovide“AllCall”signalingor
“Zone”signaling.Twoseparatezonescanbesignaledandtwoor
more control units can be ganged to monitor additional input lines.
The economical CA-312-1 model monitors three tip and ring lines.
These interface products are designed for Electronic Key Systems
andPBXor1A2systems(withtouchtonestationsets)thatdonot
offer a common audible ring circuit or dry contact closure for night
bell connection or zoned ringing.
Both models provide a choice of two outputs for connection of alert
signals: standard ringing voltage output or contact closure. A wide
selection of audible and visual alert signals is available to operate
directly off the ringing voltage output. Alternatively, Wheelock’s dry
contact interface or economy power supply can be connected to the
optional contact closure output to drive 24 VDC alert signals.
A
B
Front Cover
OUTPUT OPTIONS: 1 = Ringing Voltage
2 = ContactClosure:(useWheelock’s
DCI-24-24 or EPS-2401 to drive
24VDCalerts)